FLUKE-125B/EU - Industrial ScopeMeter

Marca:
FLUKE-125B/EU - Industrial ScopeMeter Dual-input 40 MHz Bandwidth 25 MS/s real time sampling, 2.5 GS/s equivalent time sampling Two 5,000-count true-rms digital multimeters A dual-input TrendPlot™ recorder Connect-and-View™ trigger simplicity for hands-off operation Shielded test leads for oscilloscope, resistance and continuity measurements Industrial Networks bus health testing Measure harmonics and power, VA, VAR, W, PF Up to seven hours battery operation 600 V CAT III safety certified Optically isolated RS-232 interface Bus Health Tester Resistance and Capacitance measurements. Troubleshooting a network segment starts with checking connectivity, measuring the cable impedance making sure it is not open or shorted. Ca ...
3 983,97 €
Com IVA
Disponível em Armazém Remoto 2-3 Semanas
Disponível a partir de: 2019-06-04
Referência:
4755818
Favorito0
Adicionar à lista de desejos
Produtos relacionados
Sem items
Descrição

FLUKE-125B/EU - Industrial ScopeMeter

Dual-input 40 MHz Bandwidth
25 MS/s real time sampling, 2.5 GS/s equivalent time sampling
Two 5,000-count true-rms digital multimeters
A dual-input TrendPlot™ recorder
Connect-and-View™ trigger simplicity for hands-off operation
Shielded test leads for oscilloscope, resistance and continuity measurements
Industrial Networks bus health testing
Measure harmonics and power, VA, VAR, W, PF
Up to seven hours battery operation
600 V CAT III safety certified
Optically isolated RS-232 interface
Bus Health Tester

Resistance and Capacitance measurements.
Troubleshooting a network segment starts with checking connectivity, measuring the cable impedance making sure it is not open or shorted. Cable impedance is dependant on network type, for example, Foundation Fieldbus uses a 120 Ohm cable terminated at either end of the segment with 120 Ohms. Also, check capacitance, making sure it is within specification. A good cable is essential for proper electrical signal performance.
Network signal electrical performance.
Checking electrical signal performance requires measuring key parameters of the network signal. The 125 includes a Bus Health test mode that is designed to trigger on and capture network signal waveforms. Select a bus type, the ScopeMeter Bus Health mode then runs algorithms to measure key signal parameters like bias voltages, signal low, high and peak-to-peak levels. The bus health mode also measures distortion or signal jitter determining overall signal quality.
Verify signaling meets specification.
The signal parameter measurements are compared to the industry specification, a low and high limit defined by the standard is used to determine if these key parameters are within specification. Display icons are used to clearly indicate which parameters are outside of the industry specification.
Fluctuating or incorrect bias voltages is indicative of grounding or termination issues, while low signal level measurements could mean there is excessive attenuation caused by too long cable runs, too many devices on one segment or simply incorrect network termination. Signal distortion like overshoot is a sign of reflections typically caused by cable imperfections or failing connectors.
Inspecting the signaling for disturbances is simplified with the eye pattern” display mode. The clearer the center eye” of the signal display the less distortion and disturbances on the signal. Phase noise and jitter are typical digital signal distortion caused by device receiver transmitter circuits. External electrical interference from high-energy sources such as lighting systems and heavy-duty machinery can be detected by inspecting the eye pattern.
Electrical interference like noise, static discharge and transients can cause network devices to reset, monitoring a segment can capture these events thereby helping to isolate their source.
Once the cabling and signaling parameters are eliminated, network protocol diagnostic tools are used to verify digital protocol performance.
Eliminating cabling and signal quality issues are two critical steps to isolating network performance issues. The Fluke 125 ScopeMeter includes measurement functions and algorithms to verify the integrity of network digital signaling.

Dados do produto
4755818
Opiniões
Sem comentários
16 outros produtos na mesma categoria:

Código QR

Opções

Clique para mais produtos.
Não foram encontrados produtos.

Crie uma conta gratuita para gravar produtos favoritos.

Iniciar Sessão

Criar uma conta gratuita para criar listas de desejos.

Iniciar Sessão