Fluke T5-600/62MAX+/1ACE - Thermometer,Electrical Detect Kit

Marca:
Fluke T5-600/62MAX+/1ACE - Thermometer, Electrical Tester and Voltage Detector Kit Fluke T5 Voltage, Continuity and Current Testers. Automatically measures volts AC and volts DC with precise digital resolution. Displays resistance to 1000 O. Easy and accurate OpenJaw™ current measurement. Continuity beeper. Rugged enough to withstand a 10 ft (3 m) drop. 600 V model. Auto off mode to conserve battery life. AC current. Display hold. All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed. Fluke 62 MAX+. Small in size. Big on toughness. Dust and water-resistant: IP54 rated. Rugged: 3 m (9.8 ft) drop tested. Ergonomically designed: Completely redesigned for a more natural hand fit. ...
467,40 €
Com IVA
Entrega a confirmar
Disponível a partir de: 2019-06-05
Referência:
4297126
Favorito0
Adicionar à lista de desejos
Produtos relacionados
Sem items
Descrição

Fluke T5-600/62MAX+/1ACE - Thermometer, Electrical Tester and Voltage Detector Kit

Fluke T5 Voltage, Continuity and Current Testers.
Automatically measures volts AC and volts DC with precise digital resolution.
Displays resistance to 1000 O.
Easy and accurate OpenJaw™ current measurement.
Continuity beeper.
Rugged enough to withstand a 10 ft (3 m) drop.
600 V model.
Auto off mode to conserve battery life.
AC current.
Display hold.
All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.

Fluke 62 MAX+. Small in size. Big on toughness.
Dust and water-resistant: IP54 rated.
Rugged: 3 m (9.8 ft) drop tested.
Ergonomically designed: Completely redesigned for a more natural hand fit.
Distance to spot: 12:1.
Dual lasers: Identifies area to be measured.
Large, backlit display: Makes data easier to read, even in dark areas.
C115 Deluxe soft carrying case with shoulder strap.

Specifications
Jaw opening 12.9 mm (0.5 in)
Max wire size 1/0 THHN cable
Current range AC rms 0 to 100.0 A
Accuracy AC current (50/60 Hz) 3% ± 3 counts
AC Response Averaging
Voltage range AC 0 to 600 V
Accuracy AC voltage 1.5% ± 2 counts
Voltage range DC 0 to 600 V
Accuracy DC voltage 1% ± 1 count
Resistance range 0 to 1000 O
Continuity beeper threshold On at < 25 O, off at > 400 O
Volts indicator LED threshold Guaranteed on by 30 V AC
Environmental Specifications
Operating temperature -10°C to 50°C
Storage temperature -30°C to 60°C
Humidity (without condensation) 0% to 95% (5°C to 30°C); 0% to 75% (30°C to 40°C);
0% to 45% (40°C to 50°C)
Dust/water resistance Yes
Operating altitude 2000 meters max
Temperature coefficient 0.1 x (specified accuracy)/°C (< 18°C or > 28°C)
Safety Specifications
Overvoltage category CAT III 600 V AC/DC (EN61010-1)
Agency approvals UL, CSA, and VDE
Maximum voltage Between any terminal and earth ground
Mechanical and General Specifications
Size 30.5 x 51 x 203 mm
Weight 300 g
Warranty Two-years
Battery life 200 hour zinc chloride, 400 hour alkaline
Battery type 2 x AA
Low battery indicator Yes
Current sensor opening 12.9 mm
Calibration cycle 1 year
Test leads Type Heavy duty, flexible leads rated for 1000 V use.
Field replaceable leads terminate in male shrouded banana plugs
Probes One red, one black.
Detachable Slim-Reach™ probe tips
Styles TP1 Slim Reach™ test brobes
Safety Specifications
Safety CAT IV 600 V, CAT III, 1000 V
Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010

Fluke 62 MAX+ Infrared Thermometer
Specifications
Temperature range -30°C to 650°C (-22°F to 1202°F)
Accuracy ±1.0°C or ±1.0% of reading, whichever is greater
-10°C to 0°C: ±2.0
-30°C to -10°C: ±3.0
Response time (95%) < 300 ms (95% of reading)
Spectral response 8 to 14 microns
Emissivity 0.10 to 1.00
Optical resolution 12:1 (calculated at 90% energy)
Display resolution 0.1°C (0.2°F)
Repeatability of readings ±0.5% of reading or < ±0.5°C (1°F), whichever is greater
Power AA battery
Battery life 8 hours with laser and backlight on
Physical Specifications
Weight 255 g (8.99 oz)
Size 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-4°F to 140°F), (without battery)
Operating humidity 10% to 90% RH non-condensing at 30°C (86°F)
Operating altitude 2000 meters above mean sea level
Storage altitude 12,000 meters above mean sea level
IP rating IP 54 per IEC 60529
Drop test 3 meters
Vibration and shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006
Standards and agency approval Compliance EN/IEC 61010-1: 2001
Laser safety FDA and EN 60825-1 Class II